Climatic And Geographic Design Criteria: Section R301.2, "Climatic And Geographic Design Criteria", table R301.2(1) shall be changed to read as follows:
TABLE R301.2(1)1,2

CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA

Ground Snow Load   Wind
Speede
(mph)  
Seismic Design Categoryg Subject To Damage From   Winter Design Tempf Ice Shield Underlayment Requiredi Flood
Hazardsh
Air Freezing Indexj Mean Annual Tempk
Weatheringa Frost line depthb Termitec Decayd
25 psf   90 Exposure C   B   Severe   24"   Slight to
moderate  
None to
slight  
10°F   No   CCFHAR
9/19/87  
980   51°F  

 

1. For SI: 1 pound per square foot = 0.0479 kN/ m2, 1 mile per hour = 1.609 km/h.

2. Language explaining the letters a. through k., inclusively, found in the above table, is included with the table in the international residential code and is incorporated by reference as if fully rewritten herein.